Templating Hip Arthroplasty

Authors

  • Amro Alnahhal Barnsley District General Hospital NHS Trust, Gawber Road Barnsley S75 2EP, Great Britain
  • Nayef Aslam-Pervez Barnsley District General Hospital NHS Trust, Gawber Road Barnsley S75 2EP, Great Britain
  • Hassaan Q. Sheikh South Yorkshire Rotation, Great Britain

DOI:

https://doi.org/10.3889/oamjms.2019.088

Keywords:

total hip arthroplasty, digital templating, prosthetic implant size

Abstract

BACKGROUND: Different methods have been developed and employed with variable degrees of success in pre-operative templating for total hip arthroplasty. Preoperative templating, especially digital templating, has been claimed to have increased the effectiveness of total hip arthroplasty by improving the precision of prediction of prosthetic implant size.

AIMS: The overall aim of this systematic review is to identify whether the use of pre-operative templating in total hip arthroplasty procedures has resulted in increased accuracy, reliability and precision of the procedure. Various methods of templating, like traditional acetate overlay and digital method of templating that includes a single radiographic marker and double radiographic marker methods, have been compared to establish the most reliable method of templating.

METHODS: We searched the PubMed, Google Scholar Cochrane Central Register of Controlled Trials (CENTRAL), and MEDLINE (1966 to present), EMBASE (1980 to present), CINAHL (1982 to present), Psych INFO (1967 to present) and Clinical Trials Gov.

CONCLUSION: The results of this systemic review suggest that preoperative templating is resulting in an enormous increase in the accuracy of total hip arthroplasty and among various methods, King Mark is the most reliable method.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Plum Analytics Artifact Widget Block

References

Parker MJ, Gurusamy KS, Azegami S. Arthroplasties (with and without bone cement) for proximal femoral fractures in adults. The Cochrane database of systematic reviews. 2010; 6:CD001706. https://doi.org/10.1002/14651858.CD001706.pub4

Skala-Rosenbaum J, Cech O, Dzupa V. [Arthroplasty for intracapsular fractures of the femoral neck. Current concept review]. Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca. 2012; 79(6):484-92. PMid:23286679

Garrett JC, Epstein HC, Harris WH, Harvey JP Jr, Nickel VL. Treatment of unreduced traumatic posterior dislocations of the hip. J Bone Joint Surg Am. 1979; 61:2-6. https://doi.org/10.2106/00004623-197961010-00002 PMid:759430

Austin MS, Higuera CA, Rothman RH. Total hip arthroplasty at the rothman institute. HSS journal : the musculoskeletal journal of Hospital for Special Surgery. 2012; 8(2):146-50. https://doi.org/10.1007/s11420-012-9268-x PMid:23874255 PMCid:PMC3715633

Mikhael MM, Hanssen AD, Sierra RJ. Failure of metal-on-metal total hip arthroplasty mimicking hip infection. A report of two cases. The Journal of bone and joint surgery American volume. 2009; 91(2):443-6. https://doi.org/10.2106/JBJS.H.00603 PMid:19181991

Sobieraj DM, Lee S, Coleman CI, Tongbram V, Chen W, Colby J, et al. Prolonged versus standard-duration venous thromboprophylaxis in major orthopedic surgery: a systematic review. Annals of internal medicine. 2012; 156(10):720-7. https://doi.org/10.7326/0003-4819-156-10-201205150-00423 PMid:22412039

Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. The Journal of bone and joint surgery American volume. 2001; 83-A(3):428-36. https://doi.org/10.2106/00004623-200103000-00017 PMid:11263649

Goldstein WM, Gordon A, Branson JJ. Leg length inequality in total hip arthroplasty. Orthopedics. 2005; 28(9 suppl):s1037–s1040. PMid:16190031

Rubash HE, Parvataneni HK. The pants too short, the leg too long: leg length inequality after THA. Orthopedics. 2007; 30:764–765. PMid:17899929

Kamath AF, Austin DC, Derman PB, Israelite CL. Unplanned Hip Arthroplasty Imposes Clinical and Cost Burdens on Treating Institutions. Clinical orthopaedics and related research. 2013. https://doi.org/10.1007/s11999-013-3226-x PMid:23928711 PMCid:PMC3825898

Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB. A new digital preoperative planning method for total hip arthroplasties. Clinical orthopaedics and related research. 2009; 467(4):909-16. https://doi.org/10.1007/s11999-008-0486-y PMid:18781367 PMCid:PMC2650039

Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB. A new digital preoperative planning method for total hip arthroplasties. Clinical orthopaedics and related research. 2009; 467(4):909-16. https://doi.org/10.1007/s11999-008-0486-y PMid:18781367 PMCid:PMC2650039

Blackley HR, Howell GE, Rorabeck CH. Planning and management of the difficult primary hip replacement: preoperative planning and technical considerations. Instr Course Lect. 2000; 49:3–11. PMid:10829157

Müller ME. Lessons of 30 years of total hip arthroplasty. Clin Orthop Relat Res. 1992; 274:12–21. PMid:1728996

Haddad FS, Masri BA, Garbuz DS, Duncan CP. The prevention of periprosthetic fractures in total hip and knee arthroplasty. The Orthopedic clinics of North America. 1999; 30(2):191-207. https://doi.org/10.1016/S0030-5898(05)70074-2

Cech O, Fassbender M, Kirschner P, Rozkydal Z. [Preoperative planning and surgical technic in achieving stability and leg length equality in total hip joint arthroplasty] (in Czech). Acta Chir Orthop Traumatol Cech. 2002; 69:362–368. PMid:12587498

Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br. 1998; 80:382–390. https://doi.org/10.1302/0301-620X.80B3.7764 PMid:9619923

Review Leg length inequality in total hip arthroplasty. Goldstein WM, Gordon A, Branson JJ Orthopedics. 2005; 28(9 Suppl):s1037-40. PMid:16190031

Review The prevention of periprosthetic fractures in total hip and knee arthroplasty. Haddad FS, Masri BA, Garbuz DS, Duncan CP Orthop Clin North Am. 1999; 30(2):191-207. https://doi.org/10.1016/S0030-5898(05)70074-2

Woolson ST. Leg length equalization during total hip replacement. Orthopedics. 1990; 13:17–21. PMid:2300514

Suh KT, Cheon SJ, Kim DW. Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand. 2004; 75:40–44. https://doi.org/10.1080/00016470410001708070 PMid:15022804

Wedemeyer C, Quitmann H, Xu J, Heep H, von Knoch M, Saxler G. Digital templating in total hip arthroplasty with the Mayo stem. Arch Orthop Trauma Surg. 2007.

Haddad FS, Masri BA, Garbuz DS, Duncan CP. The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am. 1999; 30:191–207. https://doi.org/10.1016/S0030-5898(05)70074-2

Schmalzried TP. Preoperative templating and biomechanics in total hip arthroplasty. Instr Course Lect. 2008; 57:273-9.

Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Canadian journal of surgery Journal canadien de chirurgie. 2009; 52(1):6-11.

Scheerlinck T. Primary hip arthroplasty templating on standard radiographs. A stepwise approach. Acta orthopaedica Belgica. 2010; 76(4):432-42. PMid:20973347

Gorski JM, Schwartz L. A device to measure x-ray magnification in preoperative planning for cementless arthroplasty. Clin Orthop Relat Res. 1986; 202:302–306. https://doi.org/10.1097/00003086-198601000-00043

Oddy M, Jones M, Pendegrass C, Pilling J, Wimhurst J. Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br. 2006; 88:581–585. https://doi.org/10.1302/0301-620X.88B5.17184 PMid:16645101

Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. The Journal of bone and joint surgery British volume. 1998; 80(3):382-90. https://doi.org/10.1302/0301-620X.80B3.7764 PMid:9619923

Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Canadian journal of surgery Journal canadien de chirurgie. 2009; 52(1):6-11.

Accuracy of digital templating in total hip arthroplasty. Whiddon DR, Bono JV, Lang JE, SmithEL, Salyapongse AK. Am J Orthop (Belle Mead NJ). 2011; 40(8):395-8. PMid:22016868

Phillips JH, Albregts AE, Kling TF, Jr., Cohen MJ. Digital radiography in pediatric orthopaedics: a prospective, controlled, and randomized trial. Journal of pediatric orthopedics. 1994; 14(3):377-80. https://doi.org/10.1097/01241398-199405000-00020 PMid:8006173

Chen B, Xiao SX, Gu PC, Lin XJ. Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study. Journal of Zhejiang University Science B. 2010; 11(9):673-80. https://doi.org/10.1631/jzus.B1000066 PMid:20803771 PMCid:PMC2932877

Mittag F, Ipach I, Schaefer R, Meisner C, Leichtle U. THA. Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician. Int Orthop. 2012; 36(9):1767-72. https://doi.org/10.3928/01477447-20120123-14

Jung S, Neuerburg C, Kappe T, Wernerus D, Reichel H, Bieger R. [Validity of digital templating in total hip arthroplasty: impact of stem design and planner's experience]. Zeitschrift fur Orthopadie und Unfallchirurgie. 2012; 150(4):404-8. PMid:22753126

Mittag F, Ipach I, Schaefer R, Meisner C, Leichtle U. Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician. Orthopedics. 2012; 35(2):e144-7. https://doi.org/10.3928/01477447-20120123-14

The accuracy of digital templating: a comparison of short-stem total hip arthroplasty andconventional total hip arthroplasty Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A. J Arthroplasty. 1995; 10(4):507-13. PMid:8523011

Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. The Journal of arthroplasty. 1995; 10(4):507-13. https://doi.org/10.1016/S0883-5403(05)80153-6

Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Canadian journal of surgery Journal canadien de chirurgie. 2009; 52(1):6-11.

Jassim SS, Ingham C, Keeling M, Wimhurst JA. Digital templating facilitates accurate leg length correction in total hip arthroplasty. Acta orthopaedica Belgica. 2012; 78(3):344-9. PMid:22822575

Olsen M, Gamble P, Chiu M, Tumia N, Boyle RA, Schemitsch EH. Assessment of accuracy and reliability in preoperative templating for hip resurfacingarthroplasty. J Zhejiang Univ Sci B. 2010; 11(9):673–680.

Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB. A new digital preoperative planning method for total hip arthroplasties. Clinical orthopaedics and related research. 2009; 467(4):909-16. https://doi.org/10.1007/s11999-008-0486-y PMid:18781367 PMCid:PMC2650039

Viceconti M, Lattanzi R, Antonietti B, Paderni S, Olmi R, Sudanese A, et al. CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning. Medical engineering & physics. 2003; 25(5):371-7. https://doi.org/10.1016/S1350-4533(03)00018-3

The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta orthopaedica. 2005; 76(1):78-84. https://doi.org/10.1080/00016470510030364 PMid:15788312

Shaarani SR, McHugh G, Collins DA. Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. The Journal of arthroplasty. 2013; 28(2):331-7. https://doi.org/10.1016/j.arth.2012.06.009 PMid:22854351

Bertz A, Indrekvam K, Ahmed M, Englund E, Sayed-Noor AS. Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system. Skeletal radiology. 2012; 41(10):1245-9. https://doi.org/10.1007/s00256-012-1431-4 PMid:22588597

Efe T, El Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J. Precision of preoperative digital templating in total hip arthroplasty. Acta orthopaedica Belgica. 2011; 77(5):616-21. PMid:22187836

Levine B, Fabi D, Deirmengian C. Digital templating in primary total hip and knee arthroplasty. Orthopedics. 2010; 33(11):797. https://doi.org/10.3928/01477447-20100924-04

Zhao X, Zhu ZA, Zhao J, Li MQ, Wang G, Yu DG, et al. The utility of digital templating in Total Hip Arthroplasty with Crowe type II and III dysplastic hips. International orthopaedics. 2011; 35(5):631-8. https://doi.org/10.1007/s00264-010-0991-y PMid:20229268 PMCid:PMC3080488

Berstock JR, Webb JC, Spencer RF. A comparison of digital and manual templating using PACS images. Annals of the Royal College of Surgeons of England. 2010; 92(1):73-4. https://doi.org/10.1308/rcsann.2010.92.1.73 PMid:20056068 PMCid:PMC3024623

Franken M, Grimm B, Heyligers I. A comparison of four systems for calibration when templating for total hip replacement with digital radiography. The Journal of bone and joint surgery British volume. 2010; 92(1):136-41. https://doi.org/10.1302/0301-620X.92B1.22257 PMid:20044692

Gamble P, de Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. The Journal of arthroplasty. 2010; 25(4):529-32. https://doi.org/10.1016/j.arth.2009.04.011 PMid:19493647

Heinert G, Hendricks J, Loeffler MD. Digital templating in hip replacement with and without radiological markers. The Journal of bone and joint surgery British volume. 2009; 91(4):459-62. https://doi.org/10.1302/0301-620X.91B4.21730 PMid:19336804

White SP, Bainbridge J, Smith EJ. Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software. Annals of the Royal College of Surgeons of England. 2008; 90(7):592-6. https://doi.org/10.1308/003588408X318101 PMid:18831869 PMCid:PMC2728308

Kulkarni A, Partington P, Kelly D, Muller S. Disc calibration for digital templating in hip replacement. The Journal of bone and joint surgery British volume. 2008; 90(12):1623-6. https://doi.org/10.1302/0301-620X.90B12.20238 PMid:19043135

Hofmann AA, Bolognesi M, Lahav A, Kurtin S. Minimizing leg-length inequality in total hip arthroplasty: use of preoperative templating and an intraoperative x-ray. American journal of orthopedics. 2008; 37(1):18-23. PMid:18309380

Wimsey S, Pickard R, Shaw G. Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. The Journal of bone and joint surgery British volume. 2006; 88(11):1508-12. https://doi.org/10.1302/0301-620X.88B11.18017 PMid:17075099

The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta orthopaedica. 2005; 76(1):78-84. https://doi.org/10.1080/00016470510030364 PMid:15788312

Sugano N, Ohzono K, Nishii T, Haraguchi K, Sakai T, Ochi T. Computed-tomography-based computer preoperative planning for total hip arthroplasty. Computer aided surgery: official journal of the International Society for Computer Aided Surgery. 1998; 3(6):320-4. https://doi.org/10.3109/10929089809148153 PMid:10379982

Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. The Journal of arthroplasty. 1995; 10(4):507-13. https://doi.org/10.1016/S0883-5403(05)80153-6

White SP, Shardlow DL. Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Annals of the Royal College of Surgeons of England. 2005; 87(1):53-4. https://doi.org/10.1308/1478708051540 PMid:15720909 PMCid:PMC1963834

Gonzalez Della Valle A, Comba F, Taveras N, Salvati EA. The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. International orthopaedics. 2008; 32(3):289-94. https://doi.org/10.1007/s00264-006-0317-2 PMid:17404731 PMCid:PMC2323429

Unnanuntana A, Wagner D, Goodman SB. The accuracy of preoperative templating in cementless total hip arthroplasty. The Journal of arthroplasty. 2009; 24(2):180-6. https://doi.org/10.1016/j.arth.2007.10.032 PMid:18534455

Goodman SB, Huene DS, Imrie S. Preoperative templating for the equalization of leg lengths in total hip arthroplasty. Contemporary orthopaedics. 1992; 24(6):703-10. PMid:10149945

Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? The Journal of arthroplasty. 2009; 24(2):175-9. https://doi.org/10.1016/j.arth.2007.11.019 PMid:18534425

Bayne CO, Krosin M, Barber TC. Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty. The Journal of arthroplasty. 2009; 24(3):407-13. https://doi.org/10.1016/j.arth.2007.11.020 PMid:18534424

Whiddon DR, Bono JV. Digital templating in total hip arthroplasty. Instructional course lectures. 2008; 57:273-9. PMid:18399591

Baxter JA, Barlow T, Karthikeyan S, Mayo DJ, King RJ. The accuracy of automatic calibration of digital pelvic radiographs using two different scale markers: a comparative study. Hip international: the journal of clinical and experimental research on hip pathology and therapy. 2012; 22(1):82-9. https://doi.org/10.5301/HIP.2012.9044 PMid:22344481

King RJ, Makrides P, Gill JA, Karthikeyan S, Krikler SJ, Griffin DR. A novel method of accurately calculating the radiological magnification of the hip. The Journal of bone and joint surgery British volume. 2009; 91(9):1217-22. https://doi.org/10.1302/0301-620X.91B9.22615 PMid:19721050

Alnahhal A, Sharma S, Hafez M, Tim Board. Accuracy of a new method of pelvic radiograph calibration: An independent comparative study. Med Eng Phys. 2003; 25(5):371-7.

Published

2019-02-23

How to Cite

1.
Alnahhal A, Aslam-Pervez N, Sheikh HQ. Templating Hip Arthroplasty. Open Access Maced J Med Sci [Internet]. 2019 Feb. 23 [cited 2024 Apr. 25];7(4):672-85. Available from: https://oamjms.eu/index.php/mjms/article/view/oamjms.2019.088

Issue

Section

F - Review Articles