Aortic Annular Enlargement during Aortic Valve Replacement
DOI:
https://doi.org/10.3889/oamjms.2016.098Keywords:
AAE-aortic annulus enlargement, Manouguian technique, PPM-patient - prosthesis mismatch, AVR-aortic valve replacement, iEOA-indexed effective orifice areaAbstract
In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.Downloads
Metrics
Plum Analytics Artifact Widget Block
References
Manouguian S, Seybold-Epting W. Patch enlargement of the aortic valve ring by extending the aortic incision to the anterior mitral leaflet. J Thorac Cardiovasc Surg. 1979;78:402—12. PMid:470420
Rahimtoola SH. The problem of valve prosthesis—patient mismatch. Circulation. 1978;58:20—4. http://dx.doi.org/10.1161/01.CIR.58.1.20 PMid:348341
Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. 2006;92:1022–1029. http://dx.doi.org/10.1136/hrt.2005.067363 PMid:16251232 PMCid:PMC1861088
Nu-ez L, Gil Aguado M, Pinto GA, Larrea JL. Enlargement of the Aortic Annulus by Resecting the Commissure Between the Left and Noncoronary Cusps. Tex Heart Inst J. 1983; 10(3): 301–303.
Nicks R, Cartmill T, Bernstein L. Hypoplasia of the aortic root: the problem of aortic valve replacement. Thorax. 1970;25:339—46. http://dx.doi.org/10.1136/thx.25.3.339 PMid:5452289 PMCid:PMC472719
Kinsley RH, Antunes MJ. Enlargement of the narrow aortic root and oblique insertion of a St. Jude prosthesis. Br Heart J. 1983;50:330—2. http://dx.doi.org/10.1136/hrt.50.4.330 PMid:6626394 PMCid:PMC481419
Coutinho GF, Correia PM, Paupe´rio G, De Oliveira F, Antunes MJ. Aortic root enlargement does not increase the surgical risk and short-term patient outcome? European Journal of Cardio-thoracic Surgery. 2011;40: 441—447. http://dx.doi.org/10.1016/j.ejcts.2010.11.064
Castro LJ, Arcidi MJ, Fisher AL, Gaudiani VA. Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch. Ann Thorac Surg. 2002;74:31—6. http://dx.doi.org/10.1016/S0003-4975(02)03680-9
St. Rammos K, Ketikoglou DG, Koullias GJ, Tsomkopoulos SG, Rammos CK, Argyrakis NP. The Nicks–Nunez posterior enlargement in the small aortic annulus:immediate–intermediate results. Interactive CardioVascular and Thoracic Surgery. 2006; 5:749–754. http://dx.doi.org/10.1510/icvts.2006.136457 PMid:17670704
Srivastava DK, Sanki P, Bhattacharya S, Siddique JV. Strategy to avoid patient-prosthesis mismatch: aortic root enlargement. Asian Cardiovasc Thorac Ann. 2014;22(2):137-41. http://dx.doi.org/10.1177/0218492312469117 PMid:24585782
LaPar DJ, Ailawadi G, Bhamidipati CM, Stukenborg G, Crosby IK, Kern JA, Kron IL. Small Prosthesis Size in Aortic Valve Replacement Does Not Affect Mortality. Ann Thorac Surg. 2011;92:880-888. http://dx.doi.org/10.1016/j.athoracsur.2011.04.105 PMid:21871273 PMCid:PMC3260881
Dhareshwar J, Sundt TM 3rd, Dearani JA, Schaff HV, Cook DJ, Orszulak TA. Aortic root enlargement: what are the operative risks? J Thorac Cardiovasc Surg. 2007;134(4):916-24. http://dx.doi.org/10.1016/j.jtcvs.2007.01.097 PMid:17903507
Peterson MD, Borger MA, Feindel CM, David TE. Aortic Annular Enlargement During Aortic Valve Replacement: Improving Results with Time. Ann Thorac Surg. 2007;83:2044 –9. http://dx.doi.org/10.1016/j.athoracsur.2007.01.059 PMid:17532393