Advantages of CAD/CAM versus Conventional Complete Dentures - A Review
DOI:
https://doi.org/10.3889/oamjms.2018.308Keywords:
CAD/CAM complete dentures, Digital complete denturesAbstract
BACKGROUND: The introduction and evolution of CAD/CAM technology into complete dentures fabrication brought high expectations in improving disadvantages associated with conventional methods.
AIM: The purpose of this review was to analyse the existing literature on computer-engineered complete dentures and to determine their advantages over the conventional dentures.
MATERIAL AND METHODS: An electronic search of the English literature from January 1994 to March 2018 was performed in PubMed/MEDLINE, using the following keywords: CAD/CAM complete dentures, computer-engineered complete dentures, complete digital dentures, complete milled dentures, and rapid prototyping dentures.
RESULTS: A total of 179 English language titles were obtained from the database, and 14 were relevant to fulfil the purpose of this review. A review of 7 articles is summarized in 2 tables for presenting a comparison between CAD/CAM and conventional dentures in clinical and laboratory studies.
CONCLUSION: Following the review of articles that discussed the comparison between CAD/CAM and conventional complete dentures in clinical studies, it can be concluded that the main advantages of CAD/CAM dentures are the reduced clinical chair time and the number of visits, digital archiving, significantly higher retention, and more favorable clinical and patient-centered outcomes. As a result of the review of laboratory studies, superior mechanical and physical properties in CAD/CAM dentures were revealed, concerning enhanced accuracy of fit of milled denture bases, less denture tooth movement and increased toughness, ultimate flexural strength, and higher elastic modulus.
Downloads
Metrics
Plum Analytics Artifact Widget Block
References
Kattadiyil MT, AlHelal A, Goodacre BJ. Clinical complications and quality assessments with computer-engineered complete dentures: A systematic review. J Prosthet Dent. 117; 6:721-728. https://doi.org/10.1016/j.prosdent.2016.12.006 PMid:28222878
Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for the removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont. 1994; 7:17-21. PMid:8179777
Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc. 2013; 41:407-16. PMid:23875432
Kawahata N, Ono H, Nishi Y, Hamano T, Nagaoka E. Trial of duplication procedure for complete dentures by CAD/CAM. J Oral Rehabil. 1997; 24:540-8. https://doi.org/10.1046/j.1365-2842.1997.00522.x PMid:9250843
Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 2011; 30:93-6. https://doi.org/10.4012/dmj.2010-112 PMid:21282882
Inokoshi M, Kanazawa M, Minakuchi S. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J. 2012; 31:40-6. https://doi.org/10.4012/dmj.2011-113 PMid:22277604
Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent. 2012; 107:34-46. https://doi.org/10.1016/S0022-3913(12)60015-8
Bilgin M, Baytaroglu E, Erdem A, Dilber, E. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication. Eur J Dent. 2016; 10:286–291. https://doi.org/10.4103/1305-7456.178304 PMid:27095912 PMCid:PMC4813451
Infante L, Yilmaz B, McGlumphy, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent. 2014; 111:351-5. https://doi.org/10.1016/j.prosdent.2013.10.014 PMid:24461946
Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD/CAM and conventional fabrication techniques. J Prosthet Dent. 2016; 107:34-36. https://doi.org/10.1016/S0022-3913(12)60015-8
Srinivasan M, Cantin Y, Mehl A, Gjengedal H, Müller F, Schimmel M. CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin Oral Investig. 2017; 21(6):2007-2019. https://doi.org/10.1007/s00784-016-1989-7 PMid:27826696
Steinmassl O, Dumfahrt H, Grunert I, Steinmassl PA. CAD/CAM produces dentures with improved fit. Clinical oral investigations. 2018:1-7. https://doi.org/10.1007/s00784-018-2369-2
Kattadiyil MT, AlHelal A. An update on computer-engineered complete dentures: A systematic review on clinical outcomes. J Prosthet Dent. 2017; 117(4):478-485. https://doi.org/10.1016/j.prosdent.2016.08.017 PMid:27881317
Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent. 2015; 114:818-825. https://doi.org/10.1016/j.prosdent.2015.08.001 PMid:26412000
Saponaro PC, Yilmaz B, Heshmati RH, McGlumphy EA. Clinical performance of CAD-CAM-fabricated complete dentures: a cross-sectional study. J Prosthet Dent. 2016; 116:431-435. https://doi.org/10.1016/j.prosdent.2016.03.017 PMid:27160780
Saponaro PC, Yilmaz B, Johnston W, Heshmati RH, McGlumphy EA. Evaluation of patient experience and satisfaction with CAD-CAM-fabricated complete denture: a retrospective survey study. J Prosthet Dent. 2016; 116:524-528. https://doi.org/10.1016/j.prosdent.2016.01.034 PMid:27402416
Schwindling FS, Stober T. A comparison of two digital techniques for the fabrication of complete removable dental prostheses: A pilot clinical study. J Prosthet Dent. 2016; 116:756-763. https://doi.org/10.1016/j.prosdent.2016.03.022 PMid:27236597
AlHelal A, AlRumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: a clinical study. J Prosthet Dent. 2016; 117(2):233–8. https://doi.org/10.1016/j.prosdent.2016.08.007 PMid:27765399
Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2018; 119(1):108-115. https://doi.org/10.1016/j.prosdent.2017.02.009 PMid:28506652
Steinmassl PA, Wiedemair V, Huck C et al. Do CAD/CAM dentures really release less monomer than conventional dentures? Clin Oral Investig. 2017; 21(5): 1697–1705. https://doi.org/10.1007/s00784-016-1961-6 PMid:27704295 PMCid:PMC5442236
Srinivasan M, Gjengedal H, Cattani-Lorente M, Moussa M, Durual S, Schimmel M, Müller F. CAD/CAM milled complete removable dental prostheses: An in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dental materials journal. 2018:2017-7. https://doi.org/10.4012/dmj.2017-207